The NSC2862 is a high-precision current sense amplifier designed for industrial and automotive applications requiring accurate current measurement. With 1% accuracy and 80V common-mode range, it provides reliable current sensing in high-voltage environments.

The device features a wide -0.3V to 80V common-mode input range, enabling both high-side and low-side current sensing in 48V and 72V systems. The fixed gain of 50V/V provides a full-scale output of 2.5V with 50mV sense voltage.

With 500kHz bandwidth, low offset voltage of 50uV, and AEC-Q100 qualification option, the NSC2862 is ideal for motor control, power supplies, and battery management systems requiring high-accuracy current measurement.

Product Series

NSC

Primary Application

Motor current sensing

Key Features

  • 1% accuracy over full temperature range
  • 80V common-mode input range
  • 500kHz bandwidth for fast response
  • 50uV max input offset voltage
  • Fixed gain of 50V/V
  • Low-side and high-side capable
  • AEC-Q100 qualified option
  • Wide operating temperature range

Specifications

Supply Voltage 2.7V to 5.5V
Channels 1 Channel
Common-Mode Range -0.3V to +80V
Gain 50V/V (fixed)
Bandwidth 500kHz
Input Offset Voltage 50uV max
Accuracy 1% max over temperature
Operating Temperature -40C to +125C
Package SOT23-6
CMRR 100dB min

Applications

Motor current sensing

Motor drive and control systems

Power supply monitoring

Power conversion and supply

Battery management systems

Battery and charging management

Solar inverter current sensing

Renewable energy systems

Industrial automation

Industrial automation and control

Automotive powertrain

Automotive and EV electronics

Documents & Resources

FAE Expert Insights

S

"The NSC2862 is my preferred choice for applications requiring better than 1% current measurement accuracy. The 80V common-mode range is a significant advantage over competitors limited to 60V, enabling direct sensing in 48V and 72V industrial systems without additional level shifting. The 1% accuracy specification includes all error sources over temperature, providing confidence in measurement integrity. I've used this device in precision motor drives where accurate torque control depends on precise current measurement. The 500kHz bandwidth handles fast transient currents while the 50uV offset ensures accuracy at low current levels. For automotive applications, the AEC-Q100 qualified version provides the reliability required for powertrain systems."

Excellent accuracy and wide common-mode range for demanding current sensing

— Senior Signal Chain FAE, BeiLuo

Frequently Asked Questions

What is the difference between NSC2860 and NSC2862?

NSC2860 and NSC2862 are both current sense amplifiers but target different accuracy requirements: NSC2860 offers 3% accuracy with 100V common-mode range, making it suitable for general-purpose current sensing where cost is a primary concern. NSC2862 offers 1% accuracy with 80V common-mode range, ideal for applications requiring higher precision. Key differences: Accuracy - NSC2862 is 3x more accurate (1% vs 3%). Common-mode range - NSC2860 handles higher voltage (100V vs 80V). Bandwidth - NSC2862 is slightly faster (500kHz vs 400kHz). Offset voltage - NSC2862 has lower offset (50uV vs 200uV). Cost - NSC2860 is more cost-effective. Choose NSC2860 for general monitoring where 3% accuracy is sufficient. Choose NSC2862 for control applications requiring precise current measurement like motor torque control or battery coulomb counting.

Use NSC2862 for precision applications requiring 1% accuracy. Use NSC2860 for general monitoring with 3% accuracy at lower cost.

nsc2860 vs nsc2862 current sense accuracy precision current measurement
How do I calculate sense resistor value for NSC2862?

Sense resistor selection for NSC2862 involves balancing accuracy, power dissipation, and voltage headroom: The NSC2862 has fixed gain of 50V/V, so output voltage = I_load × R_sense × 50. For maximum output swing of 2.5V (with 5V supply), maximum sense voltage is 50mV. Calculate R_sense = V_sense_max / I_load_max. Example: For 10A maximum current: R_sense = 50mV / 10A = 5mohm. Power dissipation: P = I² × R = 100 × 0.005 = 0.5W. Select 1W resistor for safety margin. Accuracy considerations: At 10A, 5mohm gives 50mV sense voltage. NSC2862 50uV offset contributes 0.1% error (50uV/50mV). At 1A (10% load), sense voltage is 5mV, offset contributes 1% error. For better low-current accuracy, use larger R_sense or implement system calibration. Thermal considerations: Sense resistor power dissipation causes heating. Use low-TCR resistors (<50ppm/C) to minimize resistance change with temperature.

Calculate R_sense based on maximum current and desired output voltage. Use low-TCR resistors for temperature stability. Size resistor for 2x power margin.

sense resistor calculation current sense design shunt resistor selection