Industrial Inverter Capacitor Solution
Application
Description
Complete capacitor solutions for industrial inverters including DC-Link, snubber, and control power capacitors
Core Advantages
Recommended Bill of Materials (BOM)
| Item | Part Number | Description | Quantity | Datasheet |
|---|---|---|---|---|
| 1 | CD139 10000uF/450V | DC-Link Capacitor (30-55kW) | 4 | 📄 Download |
| 2 | DC-Link 100uF/800V | Film DC-Link Capacitor (Alternative Solution) | 2 | 📄 Download |
| 3 | Snubber Capacitor 0.47uF/1200V | IGBT Snubber Capacitor | 6 | 📄 Download |
| 4 | CD11 1000uF/25V | Control Power Filter Capacitor | 10 | 📄 Download |
| 5 | Balancing Resistor 100kOhm/2W | Capacitor Balancing Resistor | 4 | 📄 Download |
Applications
Technical Specifications
Customer Success Stories
Major Inverter Manufacturer
Industrial Automation |
Challenge
Original imported brand capacitors, high cost, long lead time
Solution
Switched to Jianghai CD139 series capacitors, provided complete replacement solution
Results
Cost reduced by 30%, lead time shortened from 12 weeks to 4 weeks, product reliability reached equivalent level
Photovoltaic Inverter Manufacturer
New Energy |
Challenge
Required DC-Link capacitors with 20+ year lifespan
Solution
Adopted Jianghai DC-Link film capacitors to replace aluminum electrolytic capacitors
Results
System design lifespan reached 25 years, volume reduced by 40%, efficiency improved by 0.8%
FAE Expert Insights
Senior FAE
Applications Engineer
10+ years
Professional Insights
Industrial inverters are a key application area for Jianghai capacitors. For selection, recommend DC-Link capacitance calculated at 100-200uF per kW power, voltage rating selected at 1.25x above working voltage. For high-power inverters (>75kW), recommend film capacitor solutions, although initial cost is higher, long-term reliability is better. Note to maintain appropriate spacing during installation for heat dissipation and configure balancing resistors.
Key Takeaways
- Calculate capacitance by power: 100-200uF/kW
- Voltage margin: Rated voltage >= Working voltage x 1.25
- High-power applications prioritize film capacitors
- Pay attention to heat dissipation design, maintain appropriate spacing
- Configure balancing resistors to prevent series imbalance
Decision Framework
Decision Framework
Steps:
- Evaluate requirements
- Compare solutions
- Consult FAE