Designing effective sensor interfaces requires understanding both the sensor characteristics and the signal chain requirements. This guide covers best practices for interfacing common sensor types.

Temperature Sensor Interfaces

RTDs (Resistance Temperature Detectors): Use ratiometric measurement with precision reference resistor. 3-wire or 4-wire connection eliminates lead resistance errors. Excitation current should be limited to minimize self-heating (typically 0.5-1mA for PT100).

Thermocouples: Require cold junction compensation (CJC). Use internal temperature sensor for ±2°C accuracy, or external RTD/thermistor at connector for ±0.5°C accuracy. High-resolution ADC (≥16-bit) recommended for wide temperature ranges.

Pressure and Load Cell Interfaces

Bridge sensors (load cells, pressure sensors): Use instrumentation amplifier for high CMRR. Excitation voltage should be stable and low-noise. Ratiometric measurement eliminates excitation drift. Consider 6-wire connection for long cable runs.

Current Sensing

Shunt resistors: Choose value to minimize power loss while providing adequate signal. Use differential measurement for high-side sensing. Consider isolation for high-voltage applications. Amplifier selection depends on common-mode range and bandwidth requirements.

Noise Reduction Techniques

  • Shielding: Use shielded cables for sensor connections, connect shield at receiver end only
  • Filtering: Implement anti-aliasing filter before ADC, consider 50/60Hz notch for industrial
  • Grounding: Single-point ground connection, avoid ground loops
  • PCB Layout: Separate analog and digital sections, minimize trace lengths
  • Power Supply: Use LDOs for analog circuits, proper decoupling at each IC
  • ADC Selection for Sensor Applications

    Resolution: 16-bit for precision, 24-bit for very low signals. Sigma-delta for low-speed high-resolution, SAR for medium speed. Consider integrated PGA to reduce external components.