IND-500-250A

✓ In Stock

500V AC/DC 250A gG industrial fuse for high-current distribution and motor protection.

Product Overview

Description

The IND-500-250A is a high-current industrial fuse designed for demanding power distribution and large motor protection applications.

With 250A rating and NH2 size, this fuse handles high-power industrial loads while providing reliable protection.

The 500V rating covers standard industrial voltages up to 480V systems.

Product Series

IND

Primary Application

Large motor protection (110-132kW)

Key Features

  • 500V AC/DC rating for versatile applications
  • High 250A current rating
  • gG full-range protection
  • 100kA breaking capacity
  • NH2 size for high-current applications
  • Suitable for large motors and distribution

Specifications

Voltage Rating 500V AC / 500V DC
Current Rating 250A
Breaking Capacity 100kA @ 500V AC/DC
Size NH2 (size 2)
Mounting NH fuse base or switch
Operating Temperature -40°C to +85°C
Time-Current gG full range
Standards IEC 60269-1, UL 248-12

Applications

Large motor protection (110-132kW)

Motor drive and control systems

Main power distribution

Electronic system design

Transformer protection

Electronic system design

High-current DC systems

Electronic system design

Industrial switchgear

Industrial automation and control

Documents & Resources

FAE Expert Insights

M

"The IND-500-250A handles the high currents needed for large industrial motors and distribution. The NH2 size provides the thermal mass needed for 250A continuous operation. I use this fuse for main distribution panels and large motor protection (110kW+). The 500V rating covers standard 480V industrial systems. The equal AC/DC rating is useful for applications with both power types. The 100kA breaking capacity handles high fault currents in industrial environments."

High-current 250A fuse for large motors and main distribution

— Michael Zhang, BeiLuo

Frequently Asked Questions

When should I use NH2 vs NH1 size fuses?

NH size selection: NH00 (00) - up to 100A, compact size; NH0 (0) - up to 160A; NH1 (1) - up to 250A, most common industrial size; NH2 (2) - up to 400A; NH3 (3) - up to 630A. Select based on current rating and physical space. NH1 is most common and cost-effective for 100-250A. NH2 required for >250A. Consider: 1) Current requirement; 2) Available space; 3) Fuse base compatibility; 4) Cost - larger sizes cost more.

Use NH1 for 100-250A (most common). Use NH2 for >250A. Match fuse base to fuse size.

NH fuse size fuse base selection industrial fuse sizing