EVS-500-150A

✓ In Stock

500VDC 150A compact fuse for light EV and auxiliary circuits with 50kA breaking capacity.

Product Overview

Description

The EVS-500-150A is a compact fuse designed for light electric vehicles and auxiliary circuits in larger EVs.

With 500VDC rating and 150A current, this fuse is ideal for LCVs, electric motorcycles, and auxiliary loads.

The smaller Size 1 body saves space in compact installations while providing 50kA breaking capacity.

Product Series

EVS

Primary Application

Light commercial EVs

Key Features

  • 500VDC rating for light EV applications
  • Compact Size 1 body for space-constrained installations
  • 150A rating for auxiliary and light vehicle circuits
  • 50kA breaking capacity for reliable protection
  • Automotive temperature range
  • Cost-effective for high-volume applications

Specifications

Voltage Rating 500V DC
Current Rating 150A
Breaking Capacity 50kA @ 500V DC
Size Size 1 (51mm body)
Mounting Bolt-on M8 terminals
Operating Temperature -40°C to +125°C
Time-Current Fast-acting
Standards UL 248-13, IEC 60269-7

Applications

Light commercial EVs

Electronic system design

Electric motorcycles

Motor drive and control systems

EV auxiliary circuits

Automotive and EV electronics

DC/DC converter protection

Power conversion and supply

PTC heater circuits

Electronic system design

Documents & Resources

FAE Expert Insights

J

"The EVS-500-150A is perfect for light EV applications where space and cost are critical. I've used this fuse in electric motorcycle battery packs and LCV auxiliary circuits. The compact Size 1 body fits in tight spaces while still providing robust protection. The 150A rating is ideal for smaller battery packs and auxiliary loads like DC/DC converters and PTC heaters. The lower current rating also means lower power dissipation compared to higher-rated fuses."

Compact 500V/150A fuse for light EV and auxiliary applications

— Jennifer Liu, BeiLuo

Frequently Asked Questions

When should I use 150A vs 200A for auxiliary circuits?

Select 150A for: 1) DC/DC converters under 10kW; 2) Single PTC heaters under 5kW; 3) Small auxiliary loads with total <120A continuous. Select 200A for: 1) Larger DC/DC converters 10-15kW; 2) Multiple auxiliary loads; 3) Applications with high inrush currents. Always calculate actual maximum continuous current and apply 1.25x safety factor. Consider temperature derating at high ambient temperatures.

Calculate maximum continuous current with 1.25x safety factor. Consider inrush and temperature derating.

auxiliary fuse sizing 150A vs 200A EV auxiliary protection