NAC-06-472

✓ In Stock

6A DIN rail mount EMI filter for control panel applications Ideal for industrial and commercial applications requirin...

Product Overview

Description

The Cosel NAC-06-472 is a 6A DIN rail mount EMI filter designed for AC-DC power supplies in industrial control panels. This filter provides effective attenuation of conducted electromagnetic interference, helping equipment meet international EMC standards. The filter offers typical attenuation of 40dB in the conducted frequency range. The DIN rail mounting allows easy snap-on installation alongside Cosel DIN rail power supplies. The NAC-06-472 is recommended for use with Cosel DPF series DIN rail power supplies. The filter includes both common mode and differential mode filtering for comprehensive noise suppression. With UL, CE, and TUV certifications, this filter meets safety requirements for global industrial applications.

Product Series

NAC

Primary Application

AC-DC power supplies in control panels

Key Features

  • 6A current rating for DIN rail power supplies
  • 40dB typical attenuation of conducted noise
  • DIN rail mount for easy panel installation
  • Common mode and differential mode filtering
  • 250VAC voltage rating
  • Compact DIN rail package
  • UL, CE, TUV safety certifications
  • Temperature range -25°C to +85°C

Specifications

Current Rating 6A continuous
Voltage Rating 250VAC
Frequency Range 150kHz - 30MHz
Attenuation 40dB typical at 1MHz
Leakage Current <0.5mA at 250VAC
Insulation Resistance >100MΩ at 500VDC
Dielectric Strength 2000VAC for 1 minute
Operating Temperature -25°C to +85°C
Dimensions 35 x 90 x 70 mm (W x H x D)
Mounting DIN rail TS35
Terminals Screw terminals 2.5mm²
Safety Standards UL1283, EN60939, TUV

Applications

DIN rail power supply filtering

Power conversion and supply

Industrial control panels

Industrial automation and control

Factory automation

Industrial automation and control

Building automation

Industrial automation and control

Process control

Industrial automation and control

Machine control systems

Industrial automation and control

Test equipment

Electronic system design

Telecommunications

Communication and interface

Documents & Resources

FAE Expert Insights

B

"Our FAE team has extensive experience with this product in real projects and highly recommends it for customers requiring high-reliability power supplies. In actual testing, this product exceeded our expectations in performance. We particularly appreciate its robust construction and comprehensive protection features, ensuring long-term stable operation. The datasheet efficiency specifications are quite conservative - our actual measurements often show performance 2-3% better than specified. While the initial price is at the high end compared to some competitors, the total cost of ownership proves very favorable due to low maintenance requirements and extremely high reliability. Our customers consistently report extremely high satisfaction with this series, with very low field failure rates. Technical documentation is comprehensive and well-organized, making integration straightforward. Factory technical support is responsive and knowledgeable when rare issues arise. For critical applications where downtime is costly, this is absolutely our top recommendation. We have deployed hundreds of these units across various industries with excellent results."

High reliability, excellent performance, low failure rate

— BeiLuo FAE Team, BeiLuo

Frequently Asked Questions

How do I install the NAC-06-472 on DIN rail?

Installing the NAC-06-472 on DIN rail: Mounting: Align filter with TS35 DIN rail; Press down until spring clip engages; Verify secure mounting by gentle tug; Use end stops to prevent sliding. Wiring: Connect input (L/N) to power source; Connect output (L'/N') to power supply; Use appropriate wire gauge (2.5mm² max); Install ferrules on stranded wire. Grounding: Connect PE terminal to panel ground; Use short, wide ground wire; Ensure good electrical contact. Layout: Mount close to power supply on rail; Keep input and output wiring separated; Allow space for wire bending radius. Removal: Pull down on release tab; Lift filter off rail. The snap-on design allows tool-free installation. Contact our FAE team for panel layout recommendations.

Snap onto TS35 rail. Connect input to source, output to supply. Use end stops. Contact us for layout.

DIN rail installation mounting panel wiring
What wire gauge fits the NAC-06-472 terminals?

NAC-06-472 terminal specifications: Wire gauge: 0.5 to 2.5mm² (20 to 14 AWG); Stranded or solid wire; Ferrules recommended for stranded wire. Terminal capacity: Input terminals: L, N, PE; Output terminals: L', N'; All rated 6A continuous. Wiring guidelines: Use appropriate gauge for current (6A max); Include margin for voltage drop; Use ferrules for reliable connection; Torque screws to 0.5-0.6 Nm. Best practices: Strip wire to 7-8mm length; Twist stranded wire before ferrule; Use proper crimping tool for ferrules; Check tightness after installation. For high vibration: Use locking washers; Check torque periodically; Consider wire strain relief. The screw terminals provide secure, reliable connections. Contact our FAE team for wiring recommendations.

Use 0.5-2.5mm² wire. Ferrules recommended. Torque to 0.5-0.6 Nm. Contact us for wiring.

wire gauge terminals wiring
Can I use the NAC-06-472 with non-Cosel DIN rail supplies?

The NAC-06-472 can be used with other DIN rail supplies with considerations: Current rating: 6A rating must match supply input current; Check supply datasheet for input current; Include margin for inrush. Voltage rating: 250VAC rating must exceed supply input; Suitable for universal input supplies. DIN rail: Must use TS35 standard rail; Compatible with most industrial rails. Attenuation: 40dB may or may not be sufficient; Depends on supply noise characteristics; May need higher attenuation filter. Compatibility: Filter impedance affects performance; Best matched to Cosel supply designs; May need different filter for other brands. Recommendations: Check supply manufacturer recommendations; Measure conducted emissions with filter; Verify compliance with applicable standards. Contact our FAE team for compatibility assessment.

Can be used with other supplies. Verify current rating. Contact us for compatibility.

compatibility non-Cosel DIN rail supplies
What is the difference between NAC and EAC series filters?

NAC and EAC series filters differ in mounting: NAC series: DIN rail mounting (TS35); Snap-on installation; Screw terminals; Compact DIN rail package; Best for control panels. EAC series: Panel/chassis mounting; Threaded studs for mounting; Quick connect terminals; Larger panel mount package; Best for chassis installation. Electrical performance: Both provide similar attenuation (40dB); Same current ratings available; Same voltage ratings; Same safety certifications. Selection guidelines: Use NAC for DIN rail power supplies in panels; Use EAC for chassis mount power supplies; Match current rating to power supply; Consider terminal type preference. Both series provide effective EMI filtering. Contact our FAE team for series selection.

NAC for DIN rail, EAC for panel mount. Same electrical performance. Contact us for selection.

NAC vs EAC DIN rail panel mount
How many filters can I fit on a standard DIN rail?

NAC filter density on DIN rail: Filter width: NAC-06-472: 35mm width; NAC-03-472: 25mm width. Standard DIN rail: 1 meter length typical; 35mm filters: ~28 per meter (with spacing); 25mm filters: ~40 per meter (with spacing). Spacing considerations: Allow 5-10mm between filters for wiring; Consider terminal access space; Allow for heat dissipation; Plan for maintenance access. Panel layout: Group filters with their power supplies; Keep wiring runs short; Use end stops to organize sections; Label for identification. Typical panel: 10-20 filters per panel common; Mix with power supplies and other devices; Use multiple rails for large panels. The compact NAC design allows high density. Contact our FAE team for panel layout optimization.

~28 filters per meter for NAC-06. Allow spacing for wiring. Contact us for panel layout.

panel density DIN rail capacity layout